CaneCalc
Back to Library

Constable Small 6022

by Constable

Classic Taper

Sorry Not sure of the line weight or length this is all I have.

Line Weight

2wt

Length

6'

Geometry

hex

Pieces

2pc

Action Length

5'2"

Line Type

DT

Stations

14

Cast Length

25'

Butt-loaded (progressive/slow action)

This rod has a "Butt-loaded (progressive/slow action)" stress profile. Stress varies significantly across the rod. Some sections work much harder than others, creating a pronounced action character. Peak stress is well below the failure threshold, giving this rod a generous safety margin.

Peak Stress

114,706 osi

at 62″

Mean Stress

80,016 osi

Stress Range

114,706 osi

Uniformity

0%

Variable

Peak Stress
Low Point
Uniform Zone
Ferrule
Click dots to explore

Dimensions

StationDimensionStress
0"0.073"0
1"0.074"14,000
2"0.076"26,851
3"0.077"38,664
4"0.079"49,539
5"0.080"59,566
6"0.083"63,993
7"0.087"67,186
8"0.090"69,437
9"0.094"70,967
10"0.097"71,943
11"0.100"74,256
12"0.102"76,189
13"0.105"77,803
14"0.107"79,149
15"0.110"80,269
16"0.113"81,198
17"0.115"81,967
18"0.118"82,601
19"0.120"83,121
20"0.123"83,545
21"0.127"81,918
22"0.130"80,352
23"0.134"78,851
24"0.137"77,418
25"0.141"76,053
26"0.144"75,067
27"0.148"74,126
28"0.151"73,229
29"0.155"72,376
30"0.158"71,568
31"0.161"71,867
32"0.163"72,163
33"0.166"72,456
34"0.168"72,748
35"0.171"73,040
36"0.174"72,828
37"0.177"73,307
38"0.180"74,379
39"0.183"75,345
40"0.186"76,219
41"0.188"78,244
42"0.190"80,326
43"0.192"82,457
44"0.194"84,516
45"0.196"86,506
46"0.198"88,969
47"0.199"91,388
48"0.201"93,764
49"0.202"96,097
50"0.204"98,391
51"0.205"101,235
52"0.206"104,063
53"0.208"106,875
54"0.209"109,671
55"0.210"112,450
56"0.213"112,953
57"0.215"113,419
58"0.218"113,852
59"0.220"114,254
60"0.223"114,630
61"0.226"114,676
62"0.229"114,706
Stress profile: