CaneCalc
Back to Library

Orvis MItey Mite 5' Rod 2

by Orvis

Classic Taper

Not sure of the line weight. Hello Ray - I thought you might like to see another version of the Mitey Mite. I took this taper off a rod about 15 years ago.

Line Weight

4wt

Length

5'

Geometry

hex

Pieces

2pc

Action Length

4'2"

Line Type

DT

Stations

11

Cast Length

35'

Parabolic (butt-flex)

This rod has a "Parabolic (butt-flex)" stress profile. Stress varies significantly across the rod. Some sections work much harder than others, creating a pronounced action character. Peak stress is well below the failure threshold, giving this rod a generous safety margin.

Peak Stress

133,806 osi

at 35″

Mean Stress

105,411 osi

Stress Range

133,806 osi

Uniformity

0%

Variable

Peak Stress
Low Point
Uniform Zone
Ferrule
Click dots to explore

Dimensions

StationDimensionStress
0"0.084"0
1"0.086"17,669
2"0.089"32,851
3"0.091"45,918
4"0.094"57,179
5"0.096"66,893
6"0.098"76,675
7"0.100"85,544
8"0.101"93,594
9"0.103"100,908
10"0.105"107,560
11"0.109"106,874
12"0.113"105,759
13"0.117"104,340
14"0.121"102,714
15"0.125"100,954
16"0.127"104,360
17"0.129"107,550
18"0.130"110,540
19"0.132"113,347
20"0.134"115,985
21"0.136"116,911
22"0.139"117,703
23"0.141"118,376
24"0.144"118,946
25"0.146"119,426
26"0.149"117,910
27"0.152"116,416
28"0.156"114,951
29"0.159"113,519
30"0.162"112,320
31"0.163"116,208
32"0.164"120,752
33"0.166"125,197
34"0.167"129,548
35"0.168"133,806
36"0.171"133,197
37"0.174"132,512
38"0.178"131,764
39"0.181"130,969
40"0.184"130,135
41"0.188"128,038
42"0.192"125,994
43"0.195"124,007
44"0.199"122,077
45"0.203"120,208
46"0.208"116,361
47"0.213"112,751
48"0.218"109,362
49"0.223"106,178
50"0.228"103,184
Stress profile: